Mag-Bind® SeqDTR
$0.00 – $11,332.20
Removal of unincorporated terminators from sequencing reactions using magnetic beads
- No protocol change against major competitor
- Read lengths averaging over 800 bps (Min Phred 20)
- Manual or adjustable to automated liquid handlers
- Significant cost savings compared to sephadex-based clean ups
- 96- or 384-well formats
Excess unincorporated, non-radioactive label can cause high background fluorescence in automated sequencing gels. For optimal sequencing results, remaining labeled dideoxynucleotides should be removed prior to electrophoresis. Omega Bio-tek’s Mag-Bind® SeqDTR™ is designed to effectively and reliably remove unincorporated terminators from sequencing reactions. The system combines Omega Bio-tek’s proprietary chemistries with the reversible nucleic acid-binding properties of magnetic beads to eliminate excess nucleotides, primers, and small, non-targeted amplification products such as primer dimers. This kit is designed for both manual and fully automated purification of sequencing products.
For Research Use Only. Not for use in diagnostic procedures.
FEATURES | SPECIFICATIONS |
---|---|
Downstream application | Sanger Sequencing, Cloning, In Vitro Transcription, Nucleic Acid Labeling, PCR, Real-Time Quantitative PCR (qPCR), Sequencing, Southern Blotting |
Elution volume | 40 µL of Elution Buffer for 96-well plate protocol. 15-20 µL of Elution Buffer for 384-well plate protocol. |
Starting material | ABI Big Dye Chemistry Cycle Sequencing Reactions |
Starting amount | 5 – 20 µL |
DNA recovery | Sequencing reads start at 40 nt |
Processing mode | Automated; Manual |
Throughput | 96-384 samples per run |
DNA binding technology | Magnetic beads |
Binding capacity | Scalable |
Storage | 2°C – 8°C |
Superior Signal Strength
Figure 1. Purified 1.8 kb PCR fragments were sequenced from each company using the manufacturer’s recommended protocols. The median of 16 samples per company are used in the representations above. A 5 µL sequencing reaction was performed using a 1/32 dilution of Applied Biosystems BigDye Terminator v3.1 chemistry. DNA was analyzed on an Applied Biosystems 3730XL.
Cost Comparison
Table 1. Less BigDye is needed when using Mag-Bind SeqDTR for sample prep and clean up. Therefore reduce cost in BigDye usage. Mag-Bind SeqDTR cost per prep is significantly lower than the competitor.
Product Information
Safety Data Sheets
Components | Hazard Standards | Languages | Link | hf:tax:dlp_document_language | hf:tax:dlp_document_hazard-standard |
---|---|---|---|---|---|
Mag-Bind SeqDTR | GHS | English | english | ghs | |
Mag-Bind SeqDTR | GHS | Spanish | spanish | ghs | |
Mag-Bind SeqDTR | REACH | English | english | reach | |
Mag-Bind SeqDTR | REACH | Danish | danish | reach | |
Mag-Bind SeqDTR | REACH | Finnish | finnish | reach | |
Mag-Bind SeqDTR | REACH | French | french | reach | |
Mag-Bind SeqDTR | REACH | German | german | reach | |
Mag-Bind SeqDTR | REACH | Italian | italian | reach | |
Mag-Bind SeqDTR | REACH | Norwegian | norwegian | reach | |
Mag-Bind SeqDTR | REACH | Spanish | spanish | reach | |
Mag-Bind SeqDTR | REACH | Swedish | swedish | reach | |
Mag-Bind SeqDTR | WHMS | English | english | whms | |
Mag-Bind SeqDTR | WHMS | French | french | whms |